Komatsu FB10RS-12 won't operate, but can be switched on, and gives 'Error 20'

vendredi 21 octobre 2016

Since 'error 20' is an error on the travel motor, I took out the travel motor's PCB and found out that a few of the mosfets were busted.

I have tried to fix it by replacing a few of the busted FS70UM mosfets, and the unit worked for a few minutes, then something inside 'popped' off again after that.

I checked again, and this time it's a resistor, and still a few of the FS70UM mosfets.

I was thinking of changing the main fuse that leads from the travel motor to the travel motor PCB, to a lower value, so that if something's not right, nothing will 'pops off' in the travel motor PCB, instead will be the 'changed' fuse.

Is it possible and safe?
Attached Images
 


Komatsu FB10RS-12 won't operate, but can be switched on, and gives 'Error 20'

0 commentaires: