Hello all,

Cat 962G lifting lever electro-magnet stops being actuated when Lift angle sensor reach 500 and then lift lever goes to neutral position.
I calibrated the Lift Angle sensor as described in the manual and again the boom stop lifting itself when the sensor reach 500 in the calibration menu (7).
The value 500 corresponds nearly with the 50% of the boom height.

Can I make the magent to be actuated until the boom reach 85-90% of its height?