Been thru a lot of testing with this loader over the last few weeks
Unit has not forward or reverse control
FNR switch all checked. Clutch circuit is ok
Done the complete checks of the module but I get NO POWER to the solenoids
Pin22 has voltage, grounds on module are now ok
Cannot get voltage on pins 14,15,31,32,33 of module when going through the FNR testing stated in the manual
When KON on loader, I get a single click , pause, then 3 clicks.
I read in here only two click indicates all checks are ok - but 4???
Now the strangest thing is that the solenoids all measure EXACTLY 87.3 ohms. when tested independently. Manual state anything from 87 to 100 ohms at 20 C (68F) is ok
I am leaning to believe the module may be faulty
Can these be checked, or is there an electrical schematic for these units available???
Any assistance would be appreciated
cheers
O
Unit has not forward or reverse control
FNR switch all checked. Clutch circuit is ok
Done the complete checks of the module but I get NO POWER to the solenoids
Pin22 has voltage, grounds on module are now ok
Cannot get voltage on pins 14,15,31,32,33 of module when going through the FNR testing stated in the manual
When KON on loader, I get a single click , pause, then 3 clicks.
I read in here only two click indicates all checks are ok - but 4???
Now the strangest thing is that the solenoids all measure EXACTLY 87.3 ohms. when tested independently. Manual state anything from 87 to 100 ohms at 20 C (68F) is ok
I am leaning to believe the module may be faulty
Can these be checked, or is there an electrical schematic for these units available???
Any assistance would be appreciated
cheers